- Building Code — 1985 Regulation
Table des matières
Occurrences
0
Version courante
Texte complet
À jour au 1
er
janvier 2016
Ce document a valeur officielle.
chapter
S-2.1, r. 0.1
Building Code — 1985 Regulation
OCCUPATIONAL HEALTH AND SAFETY — A BUILDING CODE
Act respecting occupational health and safety
(chapter S-2.1, s. 223)
.
S-2.1
01
January
01
1
2016
This Regulation is applied by the Commission des normes, de l’équité, de la santé et de la sécurité du travail and concerns constructions begun after 24 January 1987 and alterations or additions made after that date. It has not been replaced or revoked and therefore continues to be applied by the CNESST.
DIVISION
I
INTERPRETATION
1
.
In this Regulation, unless the context indicates otherwise,
“building” means any structure used or intended for supporting or sheltering any use or occupancy;
“Code”: the National Building Code of Canada 1985, including the errata of October 1985 and January 1986, the revisions of January 1986, except the revisions relative to Subsection 9 of article 3.1.4.5, and the revisions of July and November 1986, January 1987 and January 1988, issued by the National Research Council of Canada.
O.C. 1958-86, s. 1
;
O.C. 996-91, s. 1
.
DIVISION
II
SCOPE
2
.
A building the construction of which began after 24 January 1987 shall conform to the Code as amended by this Regulation.
The first paragraph of this section also applies to an alteration as defined in the Code or to an addition made after the 24 January 1987 to a building built before that date.
The Regulation respecting the application of a Building Code (O.C. 912-84, 84-04-11) may apply to such a building, to its alteration or addition where work begins before 24 January 1988.
O.C. 1958-86, s. 2
.
3
.
If, in the case of an alteration as defined in the Code or of an addition to a building already built, some provisions of the Code are difficult to enforce because of their effect, the owner, to ensure safety in his building, may submit alternative measures to a person designated by the Minister of Labour, which may be accepted by that person.
O.C. 1958-86, s. 3
.
4
.
A building or part thereof of combustible construction referred to in the second paragraph of section 2 is deemed to conform to the provisions of the Code requiring noncombustible construction provided that it is equipped with a fire detection and alarm system in accordance with Subsection 3.2.4 of the Code and with a sprinkler system in accordance with Articles 3.2.5.5 and 3.2.5.7 of the Code.
O.C. 1958-86, s. 4
.
DIVISION
III
AMENDMENTS TO THE CODE
5
.
For the purposes of this Regulation, a reference in the Code to the Canadian Electrical Code, Part I, CSA C22.1-1986 is a reference to the Canadian Electrical Code, Part I (15th Edition), adopted by Order in Council 141-87 dated 28 January 1987, and to any subsequent amendments thereto.
O.C. 1958-86, s. 5
;
O.C. 996-91, s. 2
.
6
.
For the purposes of this Regulation, the Code is amended as follows:
(
1
)
the following is substituted for the definition of “
Barrier-free access
” in Subsection 1.3.2:
““
Barrier-free access”
means a path of travel designed for use by persons with an incapacity resulting from a physical or sensory disability, including persons using wheelchairs, and incorporating ramps, elevators or other lifting devices where there is a difference in elevation between floor levels along the path of travel.”;
(
2
)
the following is substituted for the definition of “
Authority having jurisdiction
” in Subsection 1.3.2:
“
“
Authority having jurisdiction”
means the Commission des normes, de l’équité, de la santé et de la sécurité du travail, established under section 137 of the Act respecting occupational health and safety (chapter S-2.1).”;
(
3
)
in Table 3.1.14.A:
(
a
)
the words “librairies, museums and skating rinks” are added at the bottom of the list headed “
Assembly uses
” in Column I headed “Type of Use of
Floor Area
or Part Thereof”; and
(
b
)
The number “3.0” is added opposite the words “librairies, museums and skating rinks” in the column headed “Area per Person in m
2
”;
(
3.1
)
the following is substituted for Sentence 9 of Article 3.1.4.5:
“
(
9
)
In addition to the exception provided for in Sentence 8, electrical wiring and cable with
combustible
jackets or sheathes may be used where one of the following conditions is fulfilled:
(
a
)
the wiring and cable does not char over more than 1.5 m when subjected to the Vertical Flame Test in Clause 4.11.4 of CSA C22.2 No. 0.3 “Test Methods for Electrical Wires and Cables”;
(
b
)
the wiring and cable are located in
i
.
noncombustible
conduit,
ii
.
concrete slabs,
iii
.
a concealed space in a wall,
iv
.
masonry walls,
v
.
a
service room
separated from the remainder of the
building
by
fire separations
having at least 1 hour
fire-resistance rating.
If the wiring and cable referred to in Sentence
b
is located in vertical shafts in
buildings
within the scope of Subsection 3.2.6, it must be enclosed in
noncombustible
conduit.”;
(
3.2
)
the following is substituted for Sentence 3 of Article 3.1.7.2:
“
(
3
)
Wiring, including single wires or groups of wires, that has
combustible
jackets or sheathes, that has an overall diameter of not more than 30 mm and that is not enclosed in
noncombustible
conduit may:
(
a
)
if it conforms to Sentence 3.1.4.5 (9)
a
, penetrate or cross an assembly required to have a
fire resistance rating
without being incorporated in the assembly at the time of testing as required in Sentence 1;
(
b
)
penetrate and cross a vertical assembly required to have a
fire-resistance rating
without being incorporated in the assembly at the time of testing as required in Sentence 1;
(
c
)
penetrate without crossing a horizontal assembly required to have a
fire-resistance rating
without being incorporated in the assembly at the time of testing as required in Sentence 1.”;
(
4
)
the following Sentence is added to Article 3.2.2.8:
“
(
3
)
The requirements in Articles 3.2.2.12 to 3.2.2.20 for roof assemblies to have a
fire resistance
rating may be waived provided that:
(
a
)
the
building
or part thereof is used exclusively for non-spectator sports and has a light
fire load
, such as indoor swimming pools, tennis courts and skating rinks;
(
b
)
the roof is of
noncombustible construction
; and
(
c
)
the roof structure is at least 6 m above the floor.”;
(
5
)
the following is substituted for clause
c
of Sentence 1 of Article 3.3.1.4:
“
(c)
except for a shooting gallery where the
occupant load
is under 10, or for a
dwelling unit
where the area of the room or
suite
or the distance measured from any point within the room or
suite
to the nearest door opening onto a
public corridor
, a corridor used by the public or a corridor serving classrooms or patients’ bedrooms or opening directly to an
exit exceeds
the values given in Table 3.3.1A;”;
(
6
)
the following article is added after Article 3.3.7.9:
“
Helicopter landing areas on roofs shall conform to the provisions of Section 2.13 of the National Fire Code of Canada 1985 (NRCC No. 23175) issued by the National Research Council of Canada.”;
(
7
)
the following is substituted for Subsection 3.3.5:
3.5.5. ELEVATORS, WHEELCHAIR PLATFORM LIFTS, DUMBWAITERS, SMALL DUMBWAITERS, ESCALATORS AND MOVING WALKS
“
(
1
)
Every elevator, wheel chair platform lift, dumbwaiter, small dumbwaiter, escalator and moving walk shall conform to the Regulation respecting elevators, dumbwaiters, escalators and moving walks (R.R.Q., 1981, c. S-3, r. 1) and any subsequent amendments thereto.
“
(
2
)
Elevators in buildings referred to in Subsection 3.2.6 shall conform to Articles 3.2.6.3 and 3.2.6.4.
“
(
3
)
Arabic numerals indicating the assigned floor (
storey
) number shall be mounted permanently on both jambs of passenger elevator hoistway entrances in accordance with Appendix E of Supplement No. 3-1982 to CSA Standard B44, “Safety Code for Elevators, Dumbwaiters, Escalators and Moving Walks.””;
(
8
)
the following is substituted for Sentence 2 of Article 3.7.2.1:
“
(
2
)
Assembly
buildings
shall have at least the number of spaces designated for wheelchair use required by Table 3.7.2.A as follows:
Tableau 3.7.2.A
___________________________________________________________________________________
Total number of Minimum number of spaces Minimum number of
seats in area or required for wheelchairs spaces required
space in buildings other than for wheelchairs
educational institutions in educational
institutions
___________________________________________________________________________________
0 - 50 1 2
51 - 100 2 4
101 - 500 2 + 1 per 100 additional 4 + 2 per 100 additional
seats or fraction thereof seats or fraction thereof
501 and over 6 + 1 per 400 additional 12 + 2 per 400
seats or fraction thereof additional seats
up to 21 spaces or fraction thereof up
to 21 spaces
___________________________________________________________________________________ ;
(
9
)
the following is substituted for Article 3.7.2.3:
“
(
1
)
In a
building
with a
barrier-free access
, at least one washroom shall be accessible and designed to accommodate handicapped persons in conformance with the appropriate requirements in Articles 3.7.3.6 to 3.7.3.9.
“
(
2
)
In addition to the washroom required in Sentence 1, where washrooms are provided for other
floor areas
with a
barrier-free access
, at least one washroom on each of these
floor areas
shall be designed to accommodate handicapped persons in accordance with the appropriate requirements in Articles 3.7.3.6 to 3.7.3.9 unless:
(
a
)
they are located within
suites of residential occupancy
; or
(
b
)
they have similar commodities.”;
(
10
)
the following is substituted for Sentence 2 of Article 3.7.3.5:
“
(
2
)
The elevating devices in Articles 3.7.2.1 shall conform to the Regulation respecting elevators, dumbwaiters, escalators and moving walks (R.R.Q., 1981, c. S-3, r. 1) and any subsequent amendments thereto.”;
(
11
)
the following is substituted for Sentence 2 of Article 4.1.1.2;
“
(
2
)
In cases covered by the Architects Act (chapter A-21), the
designer
shall be an architect, and in cases covered by the Engineers Act (chapter I-9), the
designer
shall be an engineer.”;
(
12
)
the following is substituted for Article 4.1.6.6:
“
Helicopter landing areas on roofs shall be constructed in accordance with the provisions of the document entitled “Heliport and Helideck Design Criteria” No. TP2586, issued in April 1980 by Transport Canada.”;
(
13
)
the following is substituted for Article 7.1.2.1:
“
Every
plumbing system
shall be designed and installed in accordance with the Plumbing Code (R.R.Q., 1981, c. I-12.1, r. 1), and any subsequent amendments thereto.”;
(
14
)
Part 8 entitled “Safety Measures at Construction and Demolition Sites” does not apply;
(
15
)
the words “Homes for the elderly” are added after the word “Dormitories” in the examples of Group C of A-3.1.2.A in Appendix A;
(
16
)
the number “30” is substituted for the number “25” wherever it occurs in Article 9.10.9.10.
O.C. 1958-86, s. 6
;
O.C. 996-91, s. 3
.
DIVISION
IV
TRANSITIONAL AND FINAL
7
.
Subject to the third paragraph of section 2, this Regulation replaces, for the buildings covered by that section, the Regulation respecting the application of a Building Code (O.C. 912-84, 84-04-11).
O.C. 1958-86, s. 72
.
8
.
(Omitted).
O.C. 1958-86, s. 8
.
9
.
(Omitted).
O.C. 1958-86, s. 9
.
REFERENCES
O.C. 1958-86, 1987 G.O. 2, 185
O.C. 996-91, 1991 G.O. 2, 2917
S.Q. 2015, c. 15, s. 237
Copier
Sélectionner cet élément
Sélectionner l'élément parent
Désélectionner tous les éléments
Copier vers Rédaction
Copier vers LAW
Copier vers le presse-papier
×
Pour copier : Ctrl+C
0
Nous joindre
Plan du site
Québec.ca
Accessibilité
Politique de confidentialité
© Gouvernement du Québec
Sélections
×
Afficher
Les sélections du document courant
Toutes les sélections de la collection
Fragments sélectionnés
Supprimer toutes les sélections
Afficher les sélections
Cyberlex
×
Version 2.2.4.0