30. Leachate: The operator of a sanitary landfill site must not discharge into the hydrographic surface network or into a storm sewer network any leachate containing contaminants above the standards prescribed as follows:(a) phenolic compounds: 0,02 milligram per litre;
(b) total cyanides (expressed as HCN): 0,1 milligram per litre;
(c) total sulfides (expressed as H2S): 2 milligrams per litre;
(d) cadmium (Cd): 0,1 milligram per litre;
(e) chrome (Cr): 0,5 milligram per litre;
(f) copper (Cu): 1 milligram per litre;
(g) nickel (Ni): 1 milligram per litre;
(h) zinc (Zn): 1 milligram per litre;
(i) lead (Pb): 0,1 milligram per litre;
(j) mercury (Hg): 0,001 milligram per litre;
(k) iron (Fe): 17 milligrams per litre;
(l) chlorides (expressed as Cl): 1 500 milligrams per litre;
(m) sulfates (expressed as SO4): 1 500 milligrams per litre;
(n) greases and oils: 15 milligrams per litre;
(o) total coliform bacteria: 2 400 per 100 millilitres;
(p) fecal coliform bacteria: 200 per 100 millilitres;
(q) 5-day biochemical oxygen demand (5-day BOD): 40 milligrams per litre;
(r) chemical oxygen demand: 100 milligrams per litre;
(s) odours: must not produce any of the effects enumerated in the second paragraph in fine of section 20 of the Act.