4.1.9. When there is a risk of accidental blasting by electric induction, caused notably by a radio frequency transmitter or a power line, the employer must favour a non-electrical priming method.
If the employer nonetheless carries out blasting using an electrical priming method, the employer must take all the safety measures required, including the following:(a) inform the Commission, before the work begins, of the safety measures agreed upon with public utilities where the blasting is near a power line of 125,000 V or more;
(b) place, 300 m around the loading area, signs requiring drivers to turn off the radio transmitter of their vehicle;
(c) isolate electrical circuits and make sure that the detonator leg wires are twisted together when the detonator is inserted in the firing point;
(d) make sure that all equipment emitting radio, electric or magnetic wavesi. are turned off within 15 m around the loading area before the electric detonator is assembled with the lead wires
ii. comply with the distances recommended in the Safety Guide for the Prevention of Radio Frequency Radiation Hazards in the Use of Commercial Electric Detonators, published by the Institute of Makers of Explosives (Safety Library).
O.C. 1959-86, s. 32; O.C. 57-2015, s. 10.