260. If an emergency stop occurs during automatic or semi-automatic hoisting, an alarm signal shall be activated and the hoist shall be operated only manually until the defect has been corrected. Thereafter, at least one complete cycle of descending and rising shall be made manually with the hoist.
O.C. 213-93, s. 260; O.C. 221-2009, s. 23.