133. In an underground mine, an automatic extinguishing system shall be installed:(1) on any motorized vehicle powered by a diesel engine or electric motor, on tires or tracks, manufactured after 1 April 1993 and any remote-controlled vehicle not equipped with a release device on the remote control, containing more than 100 litres (22 gallons) of hydraulic fluid other than a fluid in accordance with CSA Standard CAN/CSA-M423-M87-Fire Resistant Hydraulic Fluids;
(2) in a depot containing more than 1,000 litres (220.0 gallons) of combustible liquids and grease;
(3) on any raise climber powered by a diesel engine or electric motor; in the case of a diesel engine, the hydraulic fluid used for the climber must comply with the standard referred to in subparagraph 1;
(4) on every motorized vehicle used to transport combustible liquids in a portable tank, as defined in NFPA 30-1996, Flammable and Combustible Liquids Code;
(5) on every motorized vehicle powered by a diesel engine used in the supply of magazines or the loading of explosives underground;
(6) at portable combustible liquid supply stations with an electric pumping system, unless the system is explosion-proof.