Q-2, r. 9.01 - Design code of a storm water management system eligible for a declaration of compliance

Full text
158. The floor of the hydrodynamic separator tank installed must have an area greater than or equal to the area established using equation 4-20 for the annual suspended matter reduction performance sought.
Equation 4-20: A = Qquality/q
where:
A=Area of the floor of the frdrodynamic seperator tank (m2);
Qquality=Value of the runoff flow to be treated (m3/s);
q=Loading rate corresponding to the performance sought determined from the performance curve plotted under section 157 (m3/s/m2).
O.C. 871-2020, s. 158.
In force: 2020-12-31
158. The floor of the hydrodynamic separator tank installed must have an area greater than or equal to the area established using equation 4-20 for the annual suspended matter reduction performance sought.
Equation 4-20: A = Qquality/q
where:
A=Area of the floor of the frdrodynamic seperator tank (m2);
Qquality=Value of the runoff flow to be treated (m3/s);
q=Loading rate corresponding to the performance sought determined from the performance curve plotted under section 157 (m3/s/m2).
O.C. 871-2020, s. 158.