135.An existing side-worked prebaked anode type potline must not emit total fluorides and particles into the atmosphere in excess of the limits prescribed as of the dates indicated and set out in the following table:
Emission limit values (kg/t of aluminum produced)
Total fluorides
Particles
Date of application
Annual
4.95
15.4
1 January 2015
1.35
7
1 January 2026
Monthly
5.5
16.5
1 January 2015
1.5
8
1 January 2026
O.C. 501-2011, s. 135; O.C. 1228-2013, s. 21; O.C. 1060-2015, s. 5; 1131-2020O.C. 1131-2020, s. 11.
135.An existing side-worked prebaked anode type potline must not emit total fluorides and particles into the atmosphere in excess of the limits prescribed as of the dates indicated and set out in the following table:
Emission limit values (kg/t of aluminum produced)
Total Particle Date of application fluorides
Annual 4.95 15.4 1 January 2015
1.35 7 1 January 2021
Monthly 5.5 16.5 1 January 2015
1.5 8 1 January 2021
O.C. 501-2011, s. 135; O.C. 1228-2013, s. 21; O.C. 1060-2015, s. 5.
135.An existing side-worked prebaked anode type potline must not emit total fluorides and particles into the atmosphere in excess of the limits prescribed as of the dates indicated and set out in the following table:
Emission limit values (kg/t of aluminum produced) Total Particles Date of application fluorides Annual 4.5 14 30 June 2011 ____________________________________________________________
1.35 7 1 January 2017 Monthly 5 15 30 June 2011 ____________________________________________________________
135.An existing side-worked prebaked anode type potline must not emit total fluorides and particles into the atmosphere in excess of the limits prescribed as of the dates indicated and set out in the following table:
Emission limit values (kg/t of aluminum produced) Total fluorides Particles Date of application Annual 4.5 14 30 June 2011 ____________________________________________________________
1.35 7 1 January 2015 Monthly 5 15 30 June 2011 ____________________________________________________________