87.25. Seepage area: The total seepage area of a leaching field consisting of a seepage bed for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
__________________________________________________________________

Number of Total absorption area (square metres)
bedrooms

__________________________________________________________________

Disposal site Disposal site Disposal site is
is of high is of permeable of permeable of
permeability soil low permeability
soil soil

_________________________________________________________________

1 7 14 35
__________________________________________________________________

2 11 22 54
__________________________________________________________________

3 16 32 81
__________________________________________________________________

4 22 44 108
__________________________________________________________________

5 27 54 135
__________________________________________________________________

6 32 64 162
__________________________________________________________________
In other cases, the total seepage area of a leaching field consisting of a seepage bed must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
__________________________________________________________________

Total daily Total absorption area (square metres)
flow (litres)

__________________________________________________________________

Disposal site Disposal site Disposal site is
is of high is of permeable of permeable of
permeability soil low permeability
soil soil

__________________________________________________________________

0 to 540 7 14 35
__________________________________________________________________

541 to 1080 11 22 54
__________________________________________________________________

1081 to 1620 16 32 81
__________________________________________________________________

1621 to 2160 22 44 108
__________________________________________________________________

2161 to 2700 27 54 135
__________________________________________________________________

2701 to 3240 32 64 162
__________________________________________________________________
O.C. 786-2000, s. 69; O.C. 306-2017, s. 51.
87.25. Seepage area: The total seepage area of a leaching field consisting of a seepage bed for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
__________________________________________________________________

Number of Total absorption area (square metres)
bedrooms

__________________________________________________________________

Disposal site Disposal site Disposal site is
is of high is of permeable of permeable of
permeability soil low permeability
soil soil

_________________________________________________________________

1 7 14 35
__________________________________________________________________

2 11 22 54
__________________________________________________________________

3 16 32 81
__________________________________________________________________

4 22 44 108
__________________________________________________________________

5 27 54 135
__________________________________________________________________

6 32 64 162
__________________________________________________________________
The total seepage area of a leaching field consisting of a seepage bed for another building must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
__________________________________________________________________

Total daily Total absorption area (square metres)
flow (litres)

__________________________________________________________________

Disposal site Disposal site Disposal site is
is of high is of permeable of permeable of
permeability soil low permeability
soil soil

__________________________________________________________________

0 to 540 7 14 35
__________________________________________________________________

541 to 1080 11 22 54
__________________________________________________________________

1081 to 1620 16 32 81
__________________________________________________________________

1621 to 2160 22 44 108
__________________________________________________________________

2161 to 2700 27 54 135
__________________________________________________________________

2701 to 3240 32 64 162
__________________________________________________________________
O.C. 786-2000, s. 69.