18. Available area: The available area of the disposal site of a soil absorption field that serves an isolated dwelling must, without having to cut any trees, comply with the minimum standards in the following table, according to the origin of the effluent and the number of bedrooms:

_______________________________________________________________

Number of bedrooms Minimum available area (square metres)
_______________________________________________________________

Effluent from a Effluent from a
primary treatment secondary treatment
system system

_______________________________________________________________

1 80 53
_______________________________________________________________

2 120 80
_______________________________________________________________

3 180 120
_______________________________________________________________

4 240 160
_______________________________________________________________

5 300 200
_______________________________________________________________

6 360 240
_______________________________________________________________
In other cases, the available area of the disposal site of the soil absorption field must, without having to cut any trees, comply with the minimum standards in the following table, according to the origin of the effluent and the total daily flow:

____________________________________________________________________


Total daily flow (litres) Minimum available area (square metres)
____________________________________________________________________

Effluent from a Effluent from a
primary treatment secondary treatment
system system

____________________________________________________________________


0 to 540 80 53
____________________________________________________________________

541 to 1080 120 80
____________________________________________________________________

1081 to 1620 180 120
____________________________________________________________________

1621 to 2160 240 160
____________________________________________________________________

2161 to 2700 300 200
____________________________________________________________________

2701 to 3240 360 240
____________________________________________________________________
R.R.Q., 1981, c. Q-2, r. 8, s. 18; O.C. 786-2000, s. 23; O.C. 306-2017, s. 16.
18. Available area: The available area of the disposal site of a soil absorption field that serves an isolated dwelling must, without having to cut any trees, comply with the minimum standards in the following table, according to the origin of the effluent and the number of bedrooms:

_______________________________________________________________

Number of bedrooms Minimum available area (square metres)
_______________________________________________________________

Effluent from a Effluent from a
primary treatment secondary treatment
system system

_______________________________________________________________

1 80 53
_______________________________________________________________

2 120 80
_______________________________________________________________

3 180 120
_______________________________________________________________

4 240 160
_______________________________________________________________

5 300 200
_______________________________________________________________

6 360 240
_______________________________________________________________
The available area of the disposal site of the soil absorption field that serves another building must, without having to cut any trees, comply with the minimum standards in the following table, according to the origin of the effluent and the total daily flow:

____________________________________________________________________


Total daily flow (litres) Minimum available area (square metres)
____________________________________________________________________

Effluent from a Effluent from a
primary treatment secondary treatment
system system

____________________________________________________________________


0 to 540 80 53
____________________________________________________________________

541 to 1080 120 80
____________________________________________________________________

1081 to 1620 180 120
____________________________________________________________________

1621 to 2160 240 160
____________________________________________________________________

2161 to 2700 300 200
____________________________________________________________________

2701 to 3240 360 240
____________________________________________________________________
R.R.Q., 1981, c. Q-2, r. 8, s. 18; O.C. 786-2000, s. 23.