87.23.Trench length: The minimum total length of the absorption trenches for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
Number of Total length of trenches (metres) bedrooms ___________________________________________________________
Disposal Disposal Disposal site is of site is of site is of high permeable permeable of permeability soil low permeability soil soil ___________________________________________________________
In other cases, the minimum total length of absorption trenches must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
Total daily Total length of trenches (metres) flow (litres) ___________________________________________________________
Disposal Disposal Disposal site is of site is of site is of high permeable permeable of permeability soil low permeability soil soil ___________________________________________________________
0 to 540 12 24 58 ___________________________________________________________
541 to 1080 18 36 90 ___________________________________________________________
1081 to 1620 27 54 135 ___________________________________________________________
1621 to 2160 36 72 180 ___________________________________________________________
2161 to 2700 45 90 225 ___________________________________________________________
2701 to 3240 54 108 270 ___________________________________________________________
O.C. 786-2000, s. 69; 306-2017O.C. 306-2017, s. 491.
87.23.Trench length: The minimum total length of the absorption trenches for an isolated dwelling must comply with the following standards, according to the permeability of the disposal site and the number of bedrooms:
Number of Total length of trenches (metres) bedrooms ___________________________________________________________
Disposal Disposal Disposal site is of site is of site is of high permeable permeable of permeability soil low permeability soil soil ___________________________________________________________
The minimum total length of absorption trenches for another building must comply with the following standards, according to the permeability of the disposal site and the total daily flow:
Total daily Total length of trenches (metres) flow (litres) ___________________________________________________________
Disposal Disposal Disposal site is of site is of site is of high permeable permeable of permeability soil low permeability soil soil ___________________________________________________________
0 to 540 12 24 58 ___________________________________________________________
541 to 1080 18 36 90 ___________________________________________________________
1081 to 1620 27 54 135 ___________________________________________________________
1621 to 2160 36 72 180 ___________________________________________________________
2161 to 2700 45 90 225 ___________________________________________________________
2701 to 3240 54 108 270 ___________________________________________________________